中文关键词: 调强放疗 剂量验证 |
英文关键词:IMRT dose verification |
基金项目: |
|
摘要点击次数: 2605 |
全文下载次数: 1267 |
中文摘要: |
摘 要:[目的] 探究调强放疗计划的剂量验证方法。[方法] 利用Varian Clinal CX 4994号医用电子直线加速器出束的6MV能量X射线,对通过Eclipse 8.6治疗计划系统设计的调强放疗计划,采用PTW二维电离室矩阵进行平面剂量验证,采用Gamma分析。[结果] 86.1%(292/339)的调强放疗计划绝对剂量通过率≥90.0%。[结论] 使用二维电离室矩阵,进行调强放疗患者的个体化剂量验证,简单可靠,完善了调强放疗剂量验证体系。 |
英文摘要: |
Abstract:[Purpose] To investigate the dose verification method in the IMRT. [Methods] The IMRT plans were designed by Eclipse 8.6 TPS and were implemented in Varian Clinal CX 4994 LA with 6MV X-ray. The planes distributions of the dose were measured with PTW 2D-Array ionization chamber in the phantom.[Results] 86.1%(292/339)of the IMRT plans were ≥90% in gamma analysis method (3mm/3%) about the plane dose distribution verification. [Conclusion] The method of dose verification of IMRT is reliable and efficient in the implementation and improves the system of dose verification. |